BWRDZ - ARISTOCORT PARENTERAL AND INTRALESIONAL, ALL PRODUCT NUMBERS

  • MSDS: BWRDZ
  • Manufacturer: FUJISAWA USA INC
  • Product Name: ARISTOCORT PARENTERAL AND INTRALESIONAL, ALL PRODUCT NUMBERS
  • National Stock Number: 6505-01-210-2147
Product Identification

Product ID:ARISTOCORT PARENTERAL AND INTRALESIONAL, ALL PRODUCT NUMBERS
MSDS Date:08/20/1992
FSC:6505
NIIN:01-210-2147
MSDS Number: BWRDZ

Responsible Party
FUJISAWA USA, INC.
3 PARKWAY NORTH
DEERFIELD, IL 60015-2548
US

Emergency Phone: 708-317-0800 OR 800-888-7704

Info Phone: 708-317-0800 OR 800-888-7704

Preparer: GREGORY KOLAR

Cage: 0K706

Contractor
FUJISAWA USA, INC.
DEERFIELD, IL 60015-2548 US

Telephone: 708-317-0800 OR 800-888-7704

Cage: 0K706

Ingredients

BENZYL ALCOHOL

CAS: 100-51-6

RTECS: DN3150000


POLYETHYLENE GLYCOL

CAS: 25322-68-3

RTECS: TQ3500000


POLYSORBATE 80 (POLYOXYETHYLENESORBITOL OLEATE)

CAS: 9005-65-6

RTECS: WG2932500


SODIUM CHLORIDE

CAS: 7647-14-5

RTECS: VZ4725000


TRIAMCINOLONE DIACETATE

CAS: 67-78-7

RTECS: TU3950000


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Hazards

LD50 LC50 Mixture:TDLO INTRAMUSCULAR RAT IS 3200 UG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT IS INTENDED FOR
THEREPUTIC USE ONLY WHEN PRESCRIBED BY A PHYSICIAN. POTENTIAL
ADVERSE REACTIONS FROM PRESCTIBED DOSED & OVERDOSES ARE DESCRIBED
IN THE PACKAGE INSERT. OCCUPATIONAL EXPOSUR E HAS NOT BEEN FULLY
INVESTIGATED. FOR ADVERSE DRUG REACTION INFORMATION CALL
800-955-0321.
Explanation of Carcinogenicity:MFR GAVE NO COMMENTS OTHER THAN THE
THREE NEGATIVE LISTINGS.
Effects of Overexposure:PRIMARY IRRITATION OF THE SKIN OR EYES, FLUID
RETENTION, MUSCLE WEAKNESS, IMPAIRED HEALING OF WOUNDS, VERTIGO,
HEADACHE, CONVULSION.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
AILMENTS MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
SKIN:REMOVE CONTAMINATED CLOTHING. FLUSH W/WATER. EYE:FLUSH W/WATER
FOR 15 MIN. INHALED:NOT LIKELY TO OCCUR. INGESTED. FLUSH MOUTH OUT
W/WAT ER IMMEDIATELY & GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Lower Limits:N/EST.
Upper Limits:N/EST.
Extinguishing Media:WARER SPRAY, DRY CHEMICAL, CARBON DIOXIDE OR FOAM
AS APPROPRIATE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION IT EMITS
TOXIC FUMES OF FLUORIDE.

Accidental Release

Spill Release Procedures:USE RECOMMENDED PERSONAL PROTECTIVE EQUIPMENT.
USE ABSORBANT TOWELS OR BOOMS TO CLEAN UP SPILL. WIPE SURFACES
CLEAN & WASH WITH SOAP AND WATER.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

Handling

Handling and Storage Precautions:ASS A GENERAL RULE, WHEN HANDLING
PHARMACEUTICAL PRODUCTS, AVOID ALL CONTACT & INHALATION OF DUST,
FUME, MISTS, AND/OR VAPORS ASSOCIATED W/THE PRODUCT
Other Precautions:NONE

Exposure Controls

Respiratory Protection:WITH SATISFACTORY VENTILATION, RESPIRATORY
PROTECTION NOT USUALLY REQUIRED.
Ventilation:GENERAL ROOM VENTILATION IS USUALLY SATISFACTOYY, USE LOCAL
EXHAUST VENTILATION WHEN NECESSARY.
Protective Gloves:DISPOSABLE LATEX GLOVES RECOMMENDED
Eye Protection:SAFETY GLASSES OR GOGGLES RECOMMENDED.
Other Protective Equipment:DISPOSABLE GARMENTS IF SKIN CONTACT IS
ANTICIPATED. HMIS:EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:MFR? HMIS:USE STRICT CHEMICAL HYGIENE
PRACTICES. AVOID ALL CONTACT. WASH THOROUGHLY AFTER ANY ACCIDENTAL
CONTACT.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
NRC/State Lic Num:NONE
pH:6.0
Solubility in Water:SLIGHTLY
Appearance and Odor:CLEAR,STERILE SOLUTION, ODOR AND COLOR NOT
REPORTED.

Stability

Stability Indicator/Materials to Avoid:YES
MFR GAVE NO INFORMATION ON MSDS.
Stability Condition to Avoid:DO NOT FREEZE
Hazardous Decomposition Products:FLUORIDE FUMES
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.